EnergySaaSENERGY INTELLIGENCE
DEMO / SIMULATED · the figures come from a model, not from real measurements · model assumptions · MODEL ASSUMPTION — a range, not a promise
01 / 09DEMO / SIMULATED · the figures come from a model, not from real measurements · model assumptions

Demo tunnel car wash

Energy presentation for a car wash operator partner

One simulated day in a tunnel car wash, minute by minute: when and how much the stations consume, how much the roof produces, and what an energy storage unit changes. We compare three set-ups with the same traffic and the same weather.

  1. Agrid only
  2. Bsolar roof
  3. Csolar + energy storage
Cars / day (simulated day)313
Daily consumption289 kWh
Energy / car0.93 kWh
Annual consumption80,944 kWh365 days, COMPUTED from the model

Class-level model: machine data, traffic and tariffs are assumptions until actual measurements arrive. The demo is not connected to any equipment. Simulated day: 2026-06-20.

02 / 09DEMO / SIMULATED

How the car wash tunnel works

Cars move along the conveyor through the stations; each station consumes only while a car is in its zone. The 1-minute load is the sum of these — this curve is the shared task of the grid, the roof and the storage.

DEMO / SIMULATEDA simulated sample day from the model — not measured data, not an on-site measurement.
Loading the simulated day…
03 / 09COMPUTED from the model

Solar roof and energy storage

Set-up C: a solar roof and a small energy storage unit behind the car wash's electrical supply.

Roof (usable)120 m²MODEL ASSUMPTION
Solar PV24 kWp
Energy storage40 kWh30 kW charge / discharge power
Annual solar generation24,003 kWh
Self-sufficiency (annual)33%B: 25%
Self-consumption (simulated day)100%

What does the storage do?

  • Solar surplus → charging; it never charges from the grid.
  • On a shortfall it discharges from the part above the reserve (self-consumption).
  • The reserve is used only if the import would exceed the peak limit (peak shaving).
  • Rule-based, without foresight: no weather or traffic forecast, no price tracking.
04 / 09MODEL ASSUMPTION — a range, not a promise

Energy cost: A / B / C

Annual energy cost by set-up (range)
A · Grid onlyannual import 80,944 kWh · self-sufficiency 0%
low5.2 million HUFbase6.4 million HUFhigh8 million HUF
B · Solar PVannual import 60,435 kWh · self-sufficiency 25%
low3.9 million HUFbase4.8 million HUFhigh6.1 million HUF
C · Solar PV + batteryannual import 53,924 kWh · self-sufficiency 33%
low3.6 million HUFbase4.4 million HUFhigh5.5 million HUF

Pale bar: low–high assumption · vertical mark: base · common scale from 0

28.425A27.618.5B2518.5C
Grid peak on the sample day (import, kW) 1-minute peak (kW) 15-minute peak (kW)

The car wash's own load peak (annual maximum): 1-minute 28.5 kW, 15-minute 25 kW. The chart shows how much of it reaches the grid on the sample day.

1-minute peak: the average power over one minute. It matters for sizing the connection and the protection (circuit breaker). Start-up spikes at the one-second scale can be higher — the model does not include them.

15-minute peak: the basis of metering and billing. The contracted capacity fee is linked to it; the peak by itself is not immediate money.

05 / 09MODEL ASSUMPTION — a range, not a promise

Investment scenarios

B and C compared with set-up A (grid only). Every figure is a range: low · base · high assumption set.

B · Solar PV

MODEL ASSUMPTION — a range, not a promise
Investment
low6.7 million HUFbase8.4 million HUFhigh10.8 million HUF
Annual savings vs A
low1.2 million HUFbase1.6 million HUFhigh2.1 million HUF
Simple payback
low3.4 yearsbase5.7 yearshigh10.5 years

Simple payback = investment / (annual savings − maintenance); not NPV.

C · Solar PV + battery

MODEL ASSUMPTION — a range, not a promise
Investment
low13.9 million HUFbase18.4 million HUFhigh24.8 million HUF
Annual savings vs A
low1.6 million HUFbase2 million HUFhigh2.6 million HUF
Simple payback
low5.7 yearsbase10.5 yearshigh22 years

Simple payback, not NPV; the battery's service life (10–15 years) may be shorter than the payback period, and the replacement cost is not included.

R — backup option with a generator

Resilience — not savings

Set-up C + generator. During a grid outage the car wash can keep operating. In the financials it appears only as an extra cost (investment + fuel); we count no savings for it.

Generator
30 kW (MODEL ASSUMPTION)
Extra cost vs C
low3.6 million HUFbase5.4 million HUFhigh7.8 million HUF
Annual operating extra cost
low39 thousand HUFbase90 thousand HUFhigh178 thousand HUF

Resilience, not savings: the investment and the extra fuel cost; the benefit is that the car wash keeps operating during a grid outage. The number of outage hours is a MODEL ASSUMPTION; scaled per hour from the sample day's generator energy.

06 / 09Option — NOT legally verified

Business models

Four possible structures. None of them is legal or tax advice; each has an open question.

Own investment

Option — NOT legally verified
Who pays
The operator finances the roof and the storage.
Who benefits, and how
The operator keeps the full energy cost reduction; the system becomes part of its fixed assets.
Open question
Financing (own funds, loan, grant), depreciation and maintenance responsibility.

Energy as a service / leased system (EaaS)

Option — NOT legally verified
Who pays
A provider builds and operates it; the operator pays a monthly fee.
Who benefits, and how
No upfront investment for the operator; the provider earns long-term fee income.
Open question
Fee structure, contract term, what happens to the system at the end of the term.

PPA / selling electricity to a third party

Option — NOT legally verified
Who pays
The generating party sells the electricity it produces to the site or to a third party.
Who benefits, and how
A predictable unit price for the buyer; generation income for the investor.
Open question
Legal question: licensing and settlement under the Hungarian Electricity Act (VET) — NOT VERIFIED.

Franchise package

Option — NOT legally verified
Who pays
A standard roof + storage + monitoring package per site; the site pays a service fee.
Who benefits, and how
A repeatable, quickly deployable package; the network gets uniform data and operations.
Open question
Roof, connection and tariff differ by site — how far the package can be standardised.
07 / 09MODEL ASSUMPTION — a range, not a promise

Scaling: 1 / 10 / 50 sites

Linear extrapolation with an identical profile: every site calculated with the same traffic, roof and tariff. Volume discounts and site-specific differences are not included.

SitesInvestment (range)Annual savings (range)
1 site · set-up Clow13.9 million HUFbase18.4 million HUFhigh24.8 million HUFlow1.6 million HUFbase2 million HUFhigh2.6 million HUF
10 sites · set-up Clow139.2 million HUFbase184 million HUFhigh248 million HUFlow16.2 million HUFbase20.3 million HUFhigh25.7 million HUF
50 sites · set-up Clow0.7 billion HUFbase0.92 billion HUFhigh1.24 billion HUFlow81.1 million HUFbase101.3 million HUFhigh128.3 million HUF
08 / 09

What we need to refine the model

With these the ranges narrow and the model can be tailored to a specific site. We do not ask for personal data.

  • P0Electricity bill or 15-minute metering datacalibrating the load (kWh/car, daily profile)
  • P0Traffic: cars/day, busiest hourthe daily and hourly load
  • P0Rated power per station (kW)the peaks and the shape of the profile
  • P0Cycle and takt time, conveyor speedwhen and for how long a station consumes
  • P1Roof: usable m², orientation, tilt, structural capacitysolar generation
  • P1Tariff: energy price, charge items, contracted capacitythe range of energy cost and savings
  • P1Connection capacity (main fuse)the grid limit
09 / 09

Assumptions

Every input of the model. MODEL ASSUMPTION = our own assumption, SOURCE = referenced data.

Simulation assumptions

  • MODEL ASSUMPTION2026-06-20 local daySaturday: by the core's weekday factor, Saturday has the heaviest traffic (1.5×), so the difference between the 1-minute and the 15-minute peak is most visible here. A single simulated day, not an average day.
  • MODEL ASSUMPTION1Deterministic seed; all four configurations run with the same traffic and weather, so the load is shared.
  • MODEL ASSUMPTION0.95 clearness (0–1)Sample day: a clear Saturday in June (MODEL ASSUMPTION); the annual figures run with randomly drawn weather. The core's daily clearness is U(0.25; 1.0); 0.95 is in the top decile (≥ 0.925), below the model's ceiling (1.0). With a fixed value there is no 15-minute cloud noise either: the PV curve is smooth.
  • MODEL ASSUMPTION2026: 365 days, seed 1The annual block is the sum of one simulated year (each day with its own RNG stream derived from the date); it is not a forecast and has not been validated against measured data. R's annual block runs without an outage, so its numbers match C; it does not include the effect of the outage day.
  • MODEL ASSUMPTION30 kWConfiguration R only: a generator sized above the sample day's 1-minute peak. It runs only during a grid outage and does not charge the battery; its minimum load and start-up time are not modelled.
  • MODEL ASSUMPTION17:00–19:00 local timeConfiguration R only: grid outage 17:00–19:00 local time (evening traffic, fading PV). During the outage there is no import and no export; the shortfall is covered by the battery (from its reserve too, down to the minimum state of charge), then by the generator. If that is still not enough, the model does not shed load but flags a violation.
  • MODEL ASSUMPTIONyesDuring an outage PV is used up to the load and battery charging (hybrid inverter assumed), the rest is curtailed. NOT VERIFIED whether the actual inverter can run in island mode.
  • MODEL ASSUMPTION(load − import − genset) / loadSelf-sufficiency: the share of the load covered by solar PV and the battery; the generator is not counted.
  • MODEL ASSUMPTION1-minute average / 15-minute average kWThe 15-minute average is the basis for metering and billing; the 1-minute average is relevant for sizing the grid connection and the circuit breaker. Second-level start-up spikes are not modelled.
  • MODEL ASSUMPTION3 decimalsRounded to 3 decimals; after rounding, the per-minute balance is closed in thousandths of a kW (a single term differs from its unrounded value by at most a few thousandths of a kW).
  • MODEL ASSUMPTIONSIMULATEDSimulated demo data for an imaginary tunnel car wash; not measured and not an actual site.
  • MODEL ASSUMPTION120 m²midpoint of the 100–150 m² roof/canopy given by the owner
  • MODEL ASSUMPTION0.2 kWp/m²~430 Wp / ~2 m² module, with row spacing; internal audit 2026-11-21, annex 04, 3.4 [0.15–0.22]
  • MODEL ASSUMPTION180 °south-facing (compass azimuth: 180 = south)
  • MODEL ASSUMPTION10 °flat-roof, low-tilt frame; PVGIS Szeged 10° = 1150 kWh/kWp/year (internal audit 2026-11-21, annex 04)
  • MODEL ASSUMPTION0.86matches the 14% system loss of the PVGIS query (1 − 0.14)
  • MODEL ASSUMPTION46.253 °Szeged (region of the demo site; internal audit 2026-11-21, annex 04, 3.4)
  • MODEL ASSUMPTION20.141 °Szeged (internal audit 2026-11-21, annex 04, 3.4)
  • MODEL ASSUMPTION—None: daily clearness drawn from the seed, U(0.25; 1.0), as in engine.py
  • MODEL ASSUMPTION40 kWhinternal audit 2026-11-21, annex 04, 3.5: 40 kWh [20–100]
  • MODEL ASSUMPTION30 kWinternal audit 2026-11-21, annex 04, 3.5: 30 kW [20–50], one shared limit for charging and discharging
  • MODEL ASSUMPTION0.96one-way efficiency, the default of the existing BatteryConfig
  • MODEL ASSUMPTION10 %the default of the existing BatteryConfig
  • MODEL ASSUMPTION30 %above this level the battery serves self-consumption; below it, it discharges only for the peak limit
  • MODEL ASSUMPTION50 %start-of-day SOC, the default of the existing BatteryConfig
  • MODEL ASSUMPTION25 kWinternal audit 2026-11-21, annex 04, 3.5: peak_limit_kw default 25 kW
  • MODEL ASSUMPTION50 kW≈ 3×80 A @ 400 V (55 kVA) connection, rounded; NOT VERIFIED
  • MODEL ASSUMPTION420 min (local)opens at 07:00 (internal audit 2026-11-21, annex 04, 3.3)
  • MODEL ASSUMPTION1,260 min (local)closes at 21:00 (internal audit 2026-11-21, annex 04, 3.3)
  • MODEL ASSUMPTION[0,0,0,0,0,0,0,6,10,16,20,20,18,16,16,18,20,18,12,6,4,0,0,0] cars/h200 cars/day × hourly weights (internal audit 2026-11-21, annex 04, 3.3)
  • MODEL ASSUMPTION[0.8,0.85,0.9,0.95,1.15,1.5,0.85]Mon…Sun weekly factor (internal audit 2026-11-21, annex 04, 3.3)
  • MODEL ASSUMPTION[1.25,1.25,1.15,1.05,1,0.95,0.95,0.95,1,1,1.05,1.15]Jan…Dec, winter road salt; NOT VERIFIED (internal audit 2026-11-21, annex 04, 3.3)
  • MODEL ASSUMPTION30 cars/hmanufacturer's data sheet for the compact tunnel class: up to 30 cars/hour [SOURCE, 04 2.]
  • MODEL ASSUMPTION14.15 mmanufacturer's data sheet: the middle one of the 10.40/14.15/16.40 m conveyor lengths [SOURCE]
  • MODEL ASSUMPTION0.1 m/s6 m/min; at 30 cars/hour, 1–2 cars are inside at the same time
  • MODEL ASSUMPTION4.5 maverage passenger car
  • MODEL ASSUMPTION3 kWconveyor drive, internal audit 2026-11-21, annex 04, 3.2: 3 [1.5–4]
  • MODEL ASSUMPTION0.8part-load drive
  • MODEL ASSUMPTION2.5 kWcompressor, water recycling, water treatment while open; from the 4 kW base load in 04
  • MODEL ASSUMPTION1 kWfrost protection, water treatment while closed; from the 1.5 kW standby in 04
  • MODEL ASSUMPTION1.5 kWlighting, controls while open; from the 4 kW base load in 04
  • MODEL ASSUMPTION0.5 kWcontrols, night lighting; from the 1.5 kW standby in 04
  • MODEL ASSUMPTION2 kWpre-wash + chemical dosing, internal audit 2026-11-21, annex 04, 3.2: 2 [1–4]
  • MODEL ASSUMPTION1full load while active
  • MODEL ASSUMPTION0.5 mthin arch after the entrance
  • MODEL ASSUMPTION0.8 mactive time (0.3 + 4.5) / 0.1 = 48 s (04: 30 [20–45])
  • MODEL ASSUMPTION15 kWhigh-pressure pumps, internal audit 2026-11-21, annex 04, 3.2: 15 [7.5–22]
  • MODEL ASSUMPTION0.8pump part load
  • MODEL ASSUMPTION1.3 mthe second arch
  • MODEL ASSUMPTION2.8 mactive time (1.5 + 4.5) / 0.1 = 60 s (04: 40 [25–60])
  • MODEL ASSUMPTION5 kWrotating brushes (4–6 motors), internal audit 2026-11-21, annex 04, 3.2: 5 [3–8]
  • MODEL ASSUMPTION0.8brush motor part load
  • MODEL ASSUMPTION3.3 mstart of the brush section
  • MODEL ASSUMPTION7.3 mactive time (4 + 4.5) / 0.1 = 85 s (04: 60 [40–80])
  • MODEL ASSUMPTION3 kWrinse + wax, internal audit 2026-11-21, annex 04, 3.2: 3 [2–6]
  • MODEL ASSUMPTION1full load while active
  • MODEL ASSUMPTION7.8 mrinse arch
  • MODEL ASSUMPTION8.1 mactive time 48 s (04: 30 [20–40])
  • MODEL ASSUMPTION12 kWmanufacturer's data sheet: dryer 4 × 3 kW [SOURCE, 04 2.]; high-throughput tunnel class: 45
  • MODEL ASSUMPTION1blowers at full speed
  • MODEL ASSUMPTION8.8 mdryer section before the exit
  • MODEL ASSUMPTION11.8 mactive time (3 + 4.5) / 0.1 = 75 s (04: 60 [40–90])

Financial assumptions (range)

  • MODEL ASSUMPTION60 · 75 · 95 HUF/kWhPurchased energy + network usage charge, low-voltage business customer; NOT VERIFIED.
  • MODEL ASSUMPTION5 · 15 · 30 HUF/kWhFeed-in price for the exported surplus; NOT VERIFIED.
  • MODEL ASSUMPTION280,000 · 350,000 · 450,000 HUF/kWpInstalled rooftop solar PV, including the inverter; NOT VERIFIED.
  • MODEL ASSUMPTION180,000 · 250,000 · 350,000 HUF/kWhInstalled battery, including power electronics; NOT VERIFIED.
  • MODEL ASSUMPTION120,000 · 180,000 · 260,000 HUF/kWGenerator with automatic transfer switch, installed; NOT VERIFIED.
  • MODEL ASSUMPTION150 · 190 · 240 HUF/kWhFuel cost per kWh generated; NOT VERIFIED.
  • MODEL ASSUMPTION1 · 1.5 · 2 %/yrAnnual maintenance as a share of the investment; NOT VERIFIED.
  • MODEL ASSUMPTION20 · 25 · 30 yearsService life of the solar PV system.
  • MODEL ASSUMPTION10 · 12 · 15 yearsBattery service life; if the payback period is longer than this, a replacement is needed.
  • MODEL ASSUMPTION2 · 4 · 8 h/yrR only: annual grid outage; NOT VERIFIED.
  • SOURCE13,248 · 13,248 · 13,248 HUF/kW/yrContracted capacity fee; the metered capacity fee is 0 HUF/kW/month in the 2026 low-voltage (KIF) tariff table. Source: MEKH H2995/2025 (KIF contracted capacity fee, 2026), according to item M5 of the internal audit
  • COMPUTED25 · 25 · 25 kWConfiguration A's annual 15-minute peak, rounded up; the same for every configuration. The possible reduction of the contracted capacity with a battery is NOT included in the savings (conservative estimate).